Brookfield DV-I Viscometer Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Brookfield DV-I Viscometer herunter. Brookfield DV-I Viscometer User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 49
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Brookfield Engineering Laboratories, Inc. Page 1 Manual No. M/92-021-O604
BROOKFIELD DIGITAL VISCOMETER
MODEL DV-I+
Operating Instructions
Manual No. M/92-021-O604
Please record the Model and Serial Number of your viscometer.
Having this information readily available will help us to assist you
should there be any questions regarding your instrument.
Model No.
Serial No.
SPECIALISTS IN THE
MEASUREMENT AND
CONTROL OF VISCOSITY
TEL 800-628-8139 or 508-946-6200 FAX 508-946-6262
www.brookfieldengineering.com
BROOKFIELD ENGINEERING LABORATORIES, INC.
11 Commerce Boulevard, Middleboro, MA 02346-1031 USA
Seitenansicht 0
1 2 3 4 5 6 ... 48 49

Inhaltsverzeichnis

Seite 1 - CONTROL OF VISCOSITY

Brookfield Engineering Laboratories, Inc. Page 1 Manual No. M/92-021-O604BROOKFIELD DIGITAL VISCOMETERMODEL DV-I+Operating InstructionsManual No.

Seite 2 - TABLE OF CONTENTS

Brookfield Engineering Laboratories, Inc. Page 10 Manual No. M/92-021-O604cP 123E3 70.1°F0.0RPM % 0.0cP 0.0 S010.0RPM % 0.0(with Temperat

Seite 3 - + 57,496.0 5.7496

Brookfield Engineering Laboratories, Inc. Page 11 Manual No. M/92-021-O604NOTE: You have approximately three seconds in which to press the SELECT

Seite 4

Brookfield Engineering Laboratories, Inc. Page 12 Manual No. M/92-021-O604 II.3 Speed Selection & SettingTable II-1 shows the available speed

Seite 5

Brookfield Engineering Laboratories, Inc. Page 13 Manual No. M/92-021-O604DV-I+ is currently running. The user may operate at a given speed and p

Seite 6 - + is in the OFF position

Brookfield Engineering Laboratories, Inc. Page 14 Manual No. M/92-021-O604CGS SIViscosity cP mPa.s II.6 Temperature Display in °F or °C Selection

Seite 7

Brookfield Engineering Laboratories, Inc. Page 15 Manual No. M/92-021-O604 II.8 OperationThe following procedure is outlined for making a viscosi

Seite 8

Brookfield Engineering Laboratories, Inc. Page 16 Manual No. M/92-021-O6043. Next, the user selects the spindle number corresponding to the spindl

Seite 9 - II. GETTING STARTED

Brookfield Engineering Laboratories, Inc. Page 17 Manual No. M/92-021-O6043. At this point, the user need only press the MOTOR ON/OFF key to begin

Seite 10 - 0.0RPM % 0.0

Brookfield Engineering Laboratories, Inc. Page 18 Manual No. M/92-021-O604 TIMED TORQUESET TORQUE: 00%Figure II-22Using the UP and DOWN ARROW key

Seite 11 - 10 RPM % 89.7

Brookfield Engineering Laboratories, Inc. Page 19 Manual No. M/92-021-O604CP 123456789TIMED TORQ DONEFigure II-26The display will switch between t

Seite 12 - RPM will blink for three

Brookfield Engineering Laboratories, Inc. Page 2 Manual No. M/92-021-O604TABLE OF CONTENTS I. INTRODUCTION ...

Seite 13 - 10RPM %100.0

Brookfield Engineering Laboratories, Inc. Page 20 Manual No. M/92-021-O604Appendix A - Cone/Plate Viscometer Set-UpThis Cone/Plate version of the

Seite 14 - 10 RPM % 89.7

Brookfield Engineering Laboratories, Inc. Page 21 Manual No. M/92-021-O604Bath/CirculatorBathInletBathOutletSampleCup(CPE-44YorCPE-44P)CupOutletCu

Seite 15

Brookfield Engineering Laboratories, Inc. Page 22 Manual No. M/92-021-O604 A.3 SETTING THE GAP1. Move the toggle switch to the right; this willtur

Seite 16 - MOTOR ON OFF

Brookfield Engineering Laboratories, Inc. Page 23 Manual No. M/92-021-O604Cone Sample VolumePart No.CPE-40 0.5 mlCPE-41 2.0 mlCPE-42 1.0 mlCPE-51

Seite 17 - TIMED STOP DONE

Brookfield Engineering Laboratories, Inc. Page 24 Manual No. M/92-021-O604 Appendix B - Viscosity Ranges LV(#1-4) and RV,HA,HB(#1-7) ViscometersVi

Seite 18 - MIN: 15 SEC: 13

Brookfield Engineering Laboratories, Inc. Page 25 Manual No. M/92-021-O604 Small Sample Adapter and ThermoselSSA and Viscosity (cP) ShearThermosel

Seite 19 - TIMED TORQ DONE

Brookfield Engineering Laboratories, Inc. Page 26 Manual No. M/92-021-O604 Spiral AdapterShearRateSpiral Spindle LVDV-I+ RVDV-I+ HADV-I+ HBDV-I+ s

Seite 20 - Figure A-1

Brookfield Engineering Laboratories, Inc. Page 27 Manual No. M/92-021-O604all particle movement is in layers directed by the shearing force. For

Seite 21 - Figure A-4

Brookfield Engineering Laboratories, Inc. Page 28 Manual No. M/92-021-O604 Appendix C - Variables in Viscosity MeasurementAs with any instrument m

Seite 22 - Figure A-6

Brookfield Engineering Laboratories, Inc. Page 29 Manual No. M/92-021-O604 Viscometer Related VariablesMost fluid viscosities are found to be non-

Seite 23 - Table A-1

Brookfield Engineering Laboratories, Inc. Page 3 Manual No. M/92-021-O604 I. INTRODUCTIONThe Brookfield DV-I+ Viscometer measures fluid viscosity

Seite 24 - Vane Spindles

Brookfield Engineering Laboratories, Inc. Page 30 Manual No. M/92-021-O604 Appendix D - Spindle and Model CodesEach spindle has a two digit code w

Seite 25 - DIN Adapter Accessory

Brookfield Engineering Laboratories, Inc. Page 31 Manual No. M/92-021-O604Table D-2 lists the model codes and spring torque constants for each vis

Seite 26 - (1-100 RPM

Brookfield Engineering Laboratories, Inc. Page 32 Manual No. M/92-021-O604 Appendix E - Calibration ProceduresThe accuracy of the DV-I+ is verifi

Seite 27

Brookfield Engineering Laboratories, Inc. Page 33 Manual No. M/92-021-O604 Brookfield Viscosity Standard Fluid - General InformationWe recommend t

Seite 28

Brookfield Engineering Laboratories, Inc. Page 34 Manual No. M/92-021-O604 Calibration Procedure for a Small Sample AdapterWhen a Small Sample Ada

Seite 29

Brookfield Engineering Laboratories, Inc. Page 35 Manual No. M/92-021-O604 Calibration Procedure for UL AdapterWhen a UL Adapter is used, the wate

Seite 30 - Table D-1

Brookfield Engineering Laboratories, Inc. Page 36 Manual No. M/92-021-O604 Calibration Procedure for a Helipath Stand and T-Bar SpindlesT-Bar spin

Seite 31 - Table D-2

Brookfield Engineering Laboratories, Inc. Page 37 Manual No. M/92-021-O6044) With the viscometer stopped, remove the sample cup and place the visc

Seite 32 - °C, 93.3°C, 149°C

Brookfield Engineering Laboratories, Inc. Page 38 Manual No. M/92-021-O604The current guard leg is a band of metal in the shape of the letter U wi

Seite 33

Brookfield Engineering Laboratories, Inc. Page 39 Manual No. M/92-021-O604 Appendix F - Special Speed SetsThe following special speeds sets are av

Seite 34

Brookfield Engineering Laboratories, Inc. Page 4 Manual No. M/92-021-O604 I.1 ComponentsComponent Part Number QuantityDV-I+ Viscometer varies 1Mod

Seite 35

Brookfield Engineering Laboratories, Inc. Page 40 Manual No. M/92-021-O604 Appendix G - Communications234567891No ConnectionNo ConnectionAnalog G

Seite 36

Brookfield Engineering Laboratories, Inc. Page 41 Manual No. M/92-021-O604Figure H-1*Provided with instruments shipped after October 1, 1999. Rep

Seite 37 - SMC = 10 from Table D1

Brookfield Engineering Laboratories, Inc. Page 42 Manual No. M/92-021-O604 UnpackingCheck carefully to see that all the components are received wi

Seite 38 - LV Guardleg RV Guardleg

Brookfield Engineering Laboratories, Inc. Page 43 Manual No. M/92-021-O604Appendix I - DVE-50A Probe ClipTpProbe Clip DVE-50A is supplied with the

Seite 39 - Table F-1

Brookfield Engineering Laboratories, Inc. Page 44 Manual No. M/92-021-O604 Appendix J - Fault Diagnosis and Troubleshooting Spindle Does Not Rotat

Seite 40 - Appendix G - Communications

Brookfield Engineering Laboratories, Inc. Page 45 Manual No. M/92-021-O604 Inaccurate Readings❏ Verify Spindle, Speed and Model selection❏ Verify

Seite 41 - Figure H-1

Brookfield Engineering Laboratories, Inc. Page 46 Manual No. M/92-021-O604 Appendix K - Warranty Repair and Service WarrantyBrookfield Viscometers

Seite 42

Brookfield Engineering Laboratories, Inc. Page 47 Manual No. M/92-021-O604❏ Remove and return all spindles (properly packedfor shipping).❏ Clean e

Seite 43 - Figure I-1

Brookfield Engineering Laboratories, Inc. Page 48 Manual No. M/92-021-O604Providing us with the following information will help us to service your

Seite 44

Brookfield Engineering Laboratories, Inc. Page 49 Manual No. M/92-021-O604Appendix L - Viscosity Test ReportVISCOSITY TEST REPORTSAMPLE MODEL SPIN

Seite 45

Brookfield Engineering Laboratories, Inc. Page 5 Manual No. M/92-021-O604 I.3 SpecificationsSpeeds: LVDV-I+: 0.0, 0.3, 0.6, 1.5, 3, 6, 12, 30, 60,

Seite 46

Brookfield Engineering Laboratories, Inc. Page 6 Manual No. M/92-021-O604Tp 4) Connect the optional RTD temperature probe to the temperature port

Seite 47 - Foam Insert

Brookfield Engineering Laboratories, Inc. Page 7 Manual No. M/92-021-O604SETSPEEDSELECTSPINDLESELECTSPINDLEMOTORON/OFFAUTORANGEFigure I-1 I.6 Key

Seite 48 - TION SHEET

Brookfield Engineering Laboratories, Inc. Page 8 Manual No. M/92-021-O604 I.7 CleaningBe sure to remove spindle from instrument prior to cleaning.

Seite 49 - VISCOSITY TEST REPORT

Brookfield Engineering Laboratories, Inc. Page 9 Manual No. M/92-021-O604 II. GETTING STARTED II.1 Auto ZeroBefore readings may be taken, the Visc

Kommentare zu diesen Handbüchern

Keine Kommentare