BROOKFIELD RS-CPS+ RHEOMETEROperating InstructionsManual No. M08-218-B0212(for serial numbers beginning with “304”) SPECIALISTS IN THEMEASUREMEN
BrookeldEngineeringLabs.,Inc. Page10 ManualNo.M08-218-B0212III.2.1 TemperatureSensorThe connecting cable of the temperature sensor Pt 100
BrookeldEngineeringLabs.,Inc. Page11 ManualNo.M08-218-B0212III.2.4 ComputerConnectionIf the R/S-CPS+ Rheometer has to be used in “REMOTE” m
BrookeldEngineeringLabs.,Inc. Page12 ManualNo.M08-218-B0212The following working uids are usually used in the temperature bath:-10°C to +90°
BrookeldEngineeringLabs.,Inc. Page13 ManualNo.M08-218-B0212Peliter Control Cable INPeltier Power Supply INDrawer G Fuse5x20 1A (delay) Main S
BrookeldEngineeringLabs.,Inc. Page14 ManualNo.M08-218-B0212 IV.Environment,Handling,CleaningandMaintenance IV.1 OperatingEnvironmen
BrookeldEngineeringLabs.,Inc. Page15 ManualNo.M08-218-B0212 IV.4 MaintenanceThe R/S Rheometer system is designed for long-term operation. S
BrookeldEngineeringLabs.,Inc. Page16 ManualNo.M08-218-B0212 V.MeasuringSystemsThis section covers the various measurement geometries. Th
BrookeldEngineeringLabs.,Inc. Page17 ManualNo.M08-218-B0212Fig. 6: Setting the gap on the R/S-CPS+ RheometerSet the micrometer ring (Nonius
BrookeldEngineeringLabs.,Inc. Page18 ManualNo.M08-218-B0212 V.2 FillingtheMeasuringSystemsPlace the sample material on the bottom plate
BrookeldEngineeringLabs.,Inc. Page19 ManualNo.M08-218-B0212 VI.OperationandMenuSystemThe following section summarizes the operation and
BrookeldEngineeringLabs.,Inc. Page20 ManualNo.M08-218-B0212 VI.1 KeyboardSTOKR/S + RHEOMETERONMAIN MENU - Single measurement - Program measu
BrookeldEngineeringLabs.,Inc. Page21 ManualNo.M08-218-B0212Key Operation FunctionofKey ExampleST1) Menu2) Input of numerical values3) Sele
BrookeldEngineeringLabs.,Inc. Page22 ManualNo.M08-218-B0212 VI.2 MenuSystemofR/S-CPS+Rheometer MainMenuSingleMeasurementProgramMeasurem
BrookeldEngineeringLabs.,Inc. Page23 ManualNo.M08-218-B0212Menu HandlingSince the LCD of the R/S CPS+ Rheometer cannot show all menu items si
BrookeldEngineeringLabs.,Inc. Page24 ManualNo.M08-218-B0212Example:Select Meas.system:1) C25-2/302) C50-1/303) C50-2/30 VI.4 InputofNumeri
BrookeldEngineeringLabs.,Inc. Page25 ManualNo.M08-218-B0212Input of Values:Val.[1/s]: 0290.00Nr. of MP: 010Time[s]: 0100 Note: If you press
BrookeldEngineeringLabs.,Inc. Page26 ManualNo.M08-218-B0212THERMOSTATTS: 20.0T: 20.0Status: 00 Permanent Indication ofActual Temperature Val
BrookeldEngineeringLabs.,Inc. Page27 ManualNo.M08-218-B0212Values and Alphanumeric Texts)• Input of the measurement duration in seconds. Th
BrookeldEngineeringLabs.,Inc. Page28 ManualNo.M08-218-B0212This message will be displayed until the rst measuring point is reached and displ
BrookeldEngineeringLabs.,Inc. Page29 ManualNo.M08-218-B0212The Run Program function starts one of the available programs dened in the memory
Table of Contents I. General Description ...5 I.1 Use
BrookeldEngineeringLabs.,Inc. Page30 ManualNo.M08-218-B0212Measurements can be taken with the memory full but the results will only be shown
BrookeldEngineeringLabs.,Inc. Page31 ManualNo.M08-218-B0212VI.5.4 MAINMenu→ RemoteThe “Remote” function initiates measurements to be made
BrookeldEngineeringLabs.,Inc. Page32 ManualNo.M08-218-B0212 VI.6 MenuEntriesintheUtilitiesMenuThe Utilities menu contains several usef
BrookeldEngineeringLabs.,Inc. Page33 ManualNo.M08-218-B0212VI.6.2 Utilities → EditProgramThis function allows the input of new programs and
BrookeldEngineeringLabs.,Inc. Page34 ManualNo.M08-218-B0212The rst user dened value ( = the rst measuring point) is always the start value
BrookeldEngineeringLabs.,Inc. Page35 ManualNo.M08-218-B0212AvailableMeasurementTypes UserDenedRangeShear Rate D{s-1] Depends on the meas
BrookeldEngineeringLabs.,Inc. Page36 ManualNo.M08-218-B0212Maximum step duration: 3600 sThe instrument will automatically check the input.
BrookeldEngineeringLabs.,Inc. Page37 ManualNo.M08-218-B0212ERROR #1Printer not ready!<OK>cont. <ST>stopIf this error message app
BrookeldEngineeringLabs.,Inc. Page38 ManualNo.M08-218-B0212<OK>=storingName: C50-1/30tau_prom: 01.1418k_gamma: 01.2910Use the OK ke
BrookeldEngineeringLabs.,Inc. Page39 ManualNo.M08-218-B0212Before deleting, ensure that the data has been archived to a printer or PC. Befor
VI.6.1 Utilities → Zero Calibration ...32VI.6.2 Utilities → Edit Program ...
BrookeldEngineeringLabs.,Inc. Page40 ManualNo.M08-218-B0212VI.7.1 Conguration→ OutputModeThis function denes the output device (printer,
BrookeldEngineeringLabs.,Inc. Page41 ManualNo.M08-218-B0212Select meascount mode:-No resetting-Reset every dayResetting only via func-tion me
BrookeldEngineeringLabs.,Inc. Page42 ManualNo.M08-218-B0212VI.7.5 Conguration→RS232 ParametersThis function allows the preselection of int
BrookeldEngineeringLabs.,Inc. Page43 ManualNo.M08-218-B0212When all parameters have been selected, the new parameters are displayed:RS232: 1
BrookeldEngineeringLabs.,Inc. Page44 ManualNo.M08-218-B02121. Switch the rheometer and the PC off.2. Connect the rheometer (RS232 connector
BrookeldEngineeringLabs.,Inc. Page45 ManualNo.M08-218-B0212 VII. Measuring VII.1 MeasuringinManualOperationYou can measure in manual mo
BrookeldEngineeringLabs.,Inc. Page46 ManualNo.M08-218-B0212 VIII. Technical DataR/S-CPS+ RheometerDimensions 480 mm x 300 mm x 290 mmWeigh
BrookeldEngineeringLabs.,Inc. Page47 ManualNo.M08-218-B0212Value Symbol Physical UnitSpeed n [min-1]Torque (relative)(1000 ‰ = 50 mNm) M [1}T
BrookeldEngineeringLabs.,Inc. Page48 ManualNo.M08-218-B0212 Appendix A A.1 DataSheetsofStandardMeasuringSystemsTable A-1: Cone/Plate
BrookeldEngineeringLabs.,Inc. Page49 ManualNo.M08-218-B0212 A.2 ErrorMessagesThe R/S-CPS+ Rheometer is user-friendly regarding errors. Wh
BrookeldEngineeringLabs.,Inc. Page5 ManualNo.M08-218-B0212 I. General DescriptionThis section has general information about the instrument
BrookeldEngineeringLabs.,Inc. Page50 ManualNo.M08-218-B0212 Cause: An impermissibly high value was measured during the zero point cali-bratio
BrookeldEngineeringLabs.,Inc. Page51 ManualNo.M08-218-B0212Cause: The maximum speed has been exceeded during a measurement. Possible reasons
BrookeldEngineeringLabs.,Inc. Page52 ManualNo.M08-218-B0212The AC adapter unit of the R/S-CPS+ Rheometer permits operation of the rheometer w
BrookeldEngineeringLabs.,Inc. Page53 ManualNo.M08-218-B0212Othercountries• The connectors of the mains connecting cable must be approved a
BrookeldEngineeringLabs.,Inc. Page54 ManualNo.M08-218-B0212• R/S-CPS+ Cone/Plate Rheometer with appropriate cables• Temperature control app
BrookeldEngineeringLabs.,Inc. Page55 ManualNo.M08-218-B02121. Turn on the R/S-CPS+ Rheometer.2. Turn on the temperature controller. Set th
BrookeldEngineeringLabs.,Inc. Page56 ManualNo.M08-218-B021211. Manually turn the outside ring of the dial indicator so that the needle is on
BrookeldEngineeringLabs.,Inc. Page57 ManualNo.M08-218-B0212The R/S-CPS+ calibration check can be performed with or without software. If soft
BrookeldEngineeringLabs.,Inc. Page58 ManualNo.M08-218-B0212 StepNr1Start [‰] :250End [‰] :250Nr. Of Mp: 40time [s] : 60StepNr2Start
BrookeldEngineeringLabs.,Inc. Page59 ManualNo.M08-218-B0212Other FaultsIndication PossibleCause SolutionDial indicator reading is inconsiste
BrookeldEngineeringLabs.,Inc. Page6 ManualNo.M08-218-B0212 II. SystemCongurationThe R/S CPS+ Rheometer system consists of:• Rheometer he
BrookeldEngineeringLabs.,Inc. Page60 ManualNo.M08-218-B0212B.5.5 Cone Spindle Data Example
BrookeldEngineeringLabs.,Inc. Page61 ManualNo.M08-218-B0212www.brookeldengineering.comThe Brookeld website is a good resource for additiona
BrookeldEngineeringLabs.,Inc. Page62 ManualNo.M08-218-B0212Brookeld Viscometers are guaranteed for one year from date of purchase against de
BrookeldEngineeringLabs.,Inc. Page7 ManualNo.M08-218-B0212R/S-CPS+Rheometer1 Measuring Head of R/S-CPS+ Rheometer2 Measuring Element Coupl
BrookeldEngineeringLabs.,Inc. Page8 ManualNo.M08-218-B0212 II.2 MeasuringDevicesThe basic instrument is equipped with a temperature contro
BrookeldEngineeringLabs.,Inc. Page9 ManualNo.M08-218-B0212 III.InstrumentInstallationIn this section you will learn how to set up and use t